Validator Connector (5), Serial Port (Future use only)
This 10 pin connector, accessible from the bottom of the validator,
provides for a potential serial communication to a service tool. At present
this connector serves no function.
Customers should not connect anything to this connector.
Validator Connector (6), (Future use only)
A 6-way connector used for a MEI
®
Route Alpha hand held service tool.
At present this connector serves no function.
Customers should not connect anything to this connector.
Rotary Data and 4 Way DIL Teach Switches
In place of the option links used on an ME126 and ME129 a rotary data
switch and a 4-way DIL switch have been provided. These are accessible
through the opening in the reject cover.
The rotary data switch will enable data input to the teach functions i.e.
Token Selection.
The 4-way DIL switch can be used to enable or disable the alarm by using
switch 1 of the DIL switch or various teach functions which are accessed
via switches 2, 3 & 4.
Diagnostic LED
The LED displays a sequence of flash codes to indicate the current
operation of the validator, and can be used for fault diagnosis when
inserting coin or when teaching functions as shown below.
Flash Code Sequence:
Constantly ON Validator power on
1 Flash Coin accepted / Reject lever pressed
2 Flashes Coin not recognised and rejected
3 Flashes Coin rejected by validator 4th sensor
4 Flashes Coin recognised but not accepted due
to inhibit setting
Pre-Gate Strobes
This is an integral part of the validator which detects obstructions around
the accept gate. If an obstruction is detected then coin acceptance is
inhibited.
Post-Gate Strobes
The strobes are used for added security to the validator. These detect
coins which enter the validator using the wrong direction e.g. from the
bottom of the validator upwards. If this movement is detected the alarm
will sound.