Mars CASHFLOW 126 Guide de l'utilisateur Page 28

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 42
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 27
CashFlow
952X / 952Xe / 9510 User Guide
MEI., 2006 Page 28 Rev: G4
CF952Xe
Most of the functionality of the DIL switches on the CF952Xe are identical to the CF952X,
with the exception of the assignment and behavior of switches 1 and 2. On these models,
Serial Mode is enabled by setting SW2 ON. While SW2 is ON, SW1 operates as a serial
mode select switch. When SW1 is OFF, the serial mode selected is HII. When SW1 is
ON, the serial mode selected is ccTalk.
Do I Need to Switch the Power Off and On?
Switch up = ON
Switch down = OFF
Description Turn Power Off and On
1
Alarm Enable/ ccTalk
Not Required / Yes
2
HII Serial Mode
CcTalk Serial Mode
Yes (sw 1 OFF)
Yes (sw 1 ON)
3
Enable Coin Yes
4
Inhibit Coin Yes
5
Teach Token 1 Yes
6
Teach Token 2 Yes
7
Primary Route Teach Yes
8
Secondary Route Teach Yes
CF9510
Again, the assigment of the switches is slightly different on the CF9510. While switches 3
through 6 remain the same as in the CF952X/CF952Xe, switches 1 and 2 select the output
mode configuration. Switches 7 and 8 put the unit into Parallel Output teach mode and
Multi-pulse teach mode, respectively.
Do I Need to Switch the Power Off and On?
Switch up = ON
Switch down = OFF
Description Turn Power Off and On
1
Parallel/BCO mode Yes
2
Extended Features Yes
3
Enable Coin Yes
4
Inhibit Coin Yes
5
Teach Token 1 Yes
6
Teach Token 2 Yes
7
Primary Route Teach Yes
Vue de la page 27